Champion 73531i Owner's Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 34
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
Operation
12 Rev 73531i-20100609 E
Stopping the Engine
1. Turn off and unplug all electrical loads.
Never start or stop the generator with
electrical devices plugged in or turned
on.
2. Let the generator run at no-load for
several minutes to stabilize internal
temperatures of the engine and
generator.
3. Turn the engine switch/fuel valve to the
“Off” position.
4. Allow the generator to cool down
completely to room temperature
5. Turn the fuel cap lever vent to the “Off”
position after the generator has cooled
down completely.
Do Not Overload Generator
Capacity
Follow these simple steps to calculate the
running and starting watts necessary for
your purposes.
1. Select the electrical devices you plan on
running at the same time.
2. Total the running watts of these items.
This is the amount of power you need to
keep your items running.
3. Identify the highest starting wattage of
all devices identified in step 1. Add this
number to the number calculated in step
2. Starting wattage is the extra burst of
power needed to start some electric
driven equipment. Following the steps
listed under “Power Management” will
guarantee that only one device will be
starting at a time.
Power Management
Use the following formula to convert voltage
and amperage to watts:
Volts x Amps = Watts
To prolong the life of your generator and
attached devices, follow these steps to add
electrical load:
1. Start the generator with no electrical
load attached.
2. Allow the engine to run for several
minutes to stabilize.
3. Plug in and turn on the first item. It is
best to attach the item with the largest
load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional
item
Overload Operation
The overload indicator light will turn on
when the load exceeds 1750W. If the load
exceeds 1900W, the light will blink and cut
power to the receptacles. To recover the
power, you must shut off the engine, wait 5
seconds, and restart the generator.
Parallel Operation
Two Champion model 73531i generators can
be operated in parallel to increase the total
available electrical power to 3000 watts. A
Champion model 73500i parallel kit
(optional equipment) is required for parallel
operation. For kit availability, call Customer
Service at 1-877-338-0999 or visit
www.championpowerequipment.com.
Detailed instructions for parallel kit
installation and operation of the connected
generators are provided in the parallel kit
Owner’s Manual and Operating Instructions.
Please note the following important
requirements:
1. The two generators may be stacked one
on top of the other by aligning the lower
pads and upper pockets at each corner
of the generators.
2. Disconnect or turn off all electrical loads
from both generators.
3. The ECON switch must be in the same
position on both generators.
4. Before starting the engines, connect the
AC power outlet cables, the control
cables and the ground cables to both
generators. Follow the instructions
supplied with the parallel kit.
5. Do not disconnect any cables after the
engines have been started.
6. Start both engines and observe the green
output indicator light on both generator
panels.
7. Connect and turn on the electrical
devices.
8. The total electrical load must not exceed
3000 watts.
9. Follow the instructions on the previous
page for turning off the generators.
Page view 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 33 34

Comments to this Manuals

No comments